A9696
High End Universal Process Controller
User Manual
ABUS TECHNOLOGIES INC.
Vista de pagina 0
1 2 3 4 5 6 ... 21 22

Indice de contenidos

Pagina 1 - ABUS TECHNOLOGIES INC

A9696 High End Universal Process Controller User Manual ABUS TECHNOLOGIES INC.

Pagina 2 - HEALTH AND SAFETY

ABUS TECHNOLOGIES INC. 10 A9696 Sp.a1 ALARM 1 PRESET: Tripping point for alarm 1. Sp.a2 ALARM 2 PRESET: Tripping point for alarm 2. Sp.a3 ALARM 3 P

Pagina 3 - CATALOGUE

ABUS TECHNOLOGIES INC. 11 A9696 7.1.4 Alarm Cycle PARAMETER PROMPT PARAMETER DESCRIPTION Fva1 ALARM 1 FUNCTION: Select options from Table 7.4.2 AL

Pagina 4 - 1. INTRODUCTION

ABUS TECHNOLOGIES INC. 12 A9696 7.1.5 Configuration Cycle PARAMETER PROMPT PARAMETER DESCRIPTION type INPUT TYPE: Selects the input signal type to

Pagina 5 - 3. DIMENSIONS

ABUS TECHNOLOGIES INC. 13 A9696 7.1.6 I/O Cycle PARAMETER PROMPT PARAMETER DESCRIPTION I o 1 I/O 1 FUNCTION: Selects the I/O function to be used a

Pagina 6 - 5. CONNECTIONS

ABUS TECHNOLOGIES INC. 14 A9696 7.2 Input Type Selection Select the input type (in parameter “tYPE”) from Table below. TYPE CODE CHARACTERISTICS

Pagina 7 - 6. INSTALLATION

ABUS TECHNOLOGIES INC. 15 A9696 functions 0 to 5 only; on the other hand, I/05 can perform all 16 functions). The description fo

Pagina 8

ABUS TECHNOLOGIES INC. 16 A9696 CODE 7: Digital input - Available for I/O5, I/O6 and key F . Start/Stop input (“rvn”: Yes / No). Closed: Outp

Pagina 9 - (Green)

ABUS TECHNOLOGIES INC. 17 A9696 7.4.2 ALARM FUNCTIONS TYPE PROMPT ACTION Disabled off No active alarm. This output can be used as a digital outpu

Pagina 10

ABUS TECHNOLOGIES INC. 18 A9696 Advanced Timer Alarm (for alarms 1 or 2): ALARM FUNCTION T1 T2 ACTION Normal 0 0 Alarm Event Alarm Output Dela

Pagina 11

ABUS TECHNOLOGIES INC. 19 A9696 7.4.8 FUNCTION KEY AND DIGITAL INPUT (I/O6) FUNCTIONS Both the F key and the I/O6 digital input can be programmed

Pagina 12

ABUS TECHNOLOGIES INC. 2 A9696 WARNING  This manual should be passed on to the end user.  The contents of this manual are subject to change w

Pagina 13 - Several keystrokes at or

ABUS TECHNOLOGIES INC. 20 A9696 7.7 Ramp and Soak Profile Program Seven ramp and soak profiles with up to 7 segments each can be programmed. Longe

Pagina 14 - 7.2 Input Type Selection

ABUS TECHNOLOGIES INC. 21 A9696 Before executing the program the controller waits for PV to reach the first set point SP0 if PtoL is different than

Pagina 15

ABUS TECHNOLOGIES INC. 22 A9696 8. SAFETY PRECAUTIONS 1. The unit should be powered for 15 minutes before use. 2. Use in ambient temperature of

Pagina 16 - 7.4 Alarm Configuration

ABUS TECHNOLOGIES INC. 3 A9696 . CATALOGUE Contents Page No. 1. Introduction 4 2. Presentation 1. Features 2. Technical Parameters 4 4

Pagina 17

ABUS TECHNOLOGIES INC. 4 A9696 1. INTRODUCTION A9696 Big Digit Universal Process Controller is a real breakthrough in versatility for holding

Pagina 18 - Alarm Event

ABUS TECHNOLOGIES INC. 5 A9696 2.2 Technical Parameters  Dimensions: 96 x 96 x 92 mm. Weight: 330 g  Front panel: IP65, Polycarbonate UL94

Pagina 19

ABUS TECHNOLOGIES INC. 6 A9696 4. ORDERING DETAILS The basic unit includes one universal input, two SPST relays, two SPDT relays, 24Vdc output

Pagina 20

ABUS TECHNOLOGIES INC. 7 A9696 Controller Main Wiring Thermocouple and Voltage Wiring RTD Input Wiring Current Wiring 0 ~ 5 DC Wiring SP

Pagina 21

ABUS TECHNOLOGIES INC. 8 A9696 S.No. Parameters Description 1 A1-A4 Show active alarms. 2 COM Flashes when communication messages are sent by the

Pagina 22

ABUS TECHNOLOGIES INC. 9 A9696 7. CONFIGURATION 7.1 Programming the Indicator 7.1.1 Operation Cycle PARAMETER PROMPT PARAMETER DESCRIPTION P