Abus-technologies DP Series Smart Pressure Transmitter Manual de usuario

Busca en linea o descarga Manual de usuario para Sensores Abus-technologies DP Series Smart Pressure Transmitter. ABUS Technologies DP Series Smart Pressure Transmitter User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 15
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
DPT
Smart Pressure/DP Transmitter
User Manual
ABUS TECHNOLOGIES INC.
Flanged Diaphragm
Type
Vista de pagina 0
1 2 3 4 5 6 ... 14 15

Indice de contenidos

Pagina 1 - ABUS TECHNOLOGIES INC

DPT Smart Pressure/DP Transmitter User Manual ABUS TECHNOLOGIES INC. Flanged Diaphragm Type

Pagina 2

ABUS TECHNOLOGIES INC. M94 10 head or test. The power supply goes to the transmitter through the signal line, with no need of additional wiring.

Pagina 3 - CATALOGUE

ABUS TECHNOLOGIES INC. M94 11 4. ORDERING DETAILS TYPE DESCRIPTION Product M94 Smart Transmitter with HART Communication Type DP

Pagina 4

ABUS TECHNOLOGIES INC. M94 12 5. ORDERING DETAILS (Micro Differential Transmitter) TYPE DESCRIPTION Product M94 Smart Transmitter with

Pagina 5

ABUS TECHNOLOGIES INC. M94 13 With Sealing Groove FLANGED DIAPHRAGM DP TRANSMITTER (LEVEL TRANSMITTER) Static Pressure and Overpressure L

Pagina 6

ABUS TECHNOLOGIES INC. M94 14 6. ORDERING DETAILS (M94DL) TYPE DESCRIPTION Product M94 Smart Transmitter with HART Communication Type

Pagina 7

ABUS TECHNOLOGIES INC. M94 15 7. SAFETY PRECAUTIONS 1. The unit should be powered for 15 minutes before use. 2. Use in ambient temperature of 0

Pagina 8 - 2.4.1 Push Button Functions

ABUS TECHNOLOGIES INC. M94 2 WARNING v This manual should be passed on to the end user. v The contents of this manual are subject to change wit

Pagina 9 - 3. ELECTRICAL CONNECTIONS

ABUS TECHNOLOGIES INC. M94 3 CATALOGUE Contents Page No. 1. Introduction 4 2. Presentation 1. Structure Overview 2. Working Principl

Pagina 10

ABUS TECHNOLOGIES INC. M94 4 1. INTRODUCTION The ABUS DP Series features high performance with high degree of precision. Differential

Pagina 11 - 4. ORDERING DETAILS

ABUS TECHNOLOGIES INC. M94 5 Description 2.2 Working Principle As indicated in the working principle diagram, the outside pressure or

Pagina 12 - Example: M94 MD 12 L22 D

ABUS TECHNOLOGIES INC. M94 6 2.3 Dimensions M Type 1200 1300 1400 1500 1600 1700 1800 1900 1000 2300 Size (mm) 54 55.6 57.2 58.4

Pagina 13 - DP Transmitters

ABUS TECHNOLOGIES INC. M94 7 Mounting Orientation Effect: Zero drifts no more than 0.24kPa. No effect for movement parallel to diaphragm.

Pagina 14 - 6. ORDERING DETAILS (M94DL)

ABUS TECHNOLOGIES INC. M94 8 2.4.1 Push Button Functions 1. Zero & Span Shift Zero Shift : push key S & Z at the same time (key S on the l

Pagina 15

ABUS TECHNOLOGIES INC. M94 9 3. ELECTRICAL CONNECTIONS Electrical Port: :NPT1/2 load resistance of cable sealed connector: (4-20m

Comentarios a estos manuales